. A complete Parts List is available at www.MillerWelds.com
OM-254 170 Page 24
Ref. 254 087-A
5-6. Sequence Of Gouging Operation
Connect work clamp to a clean, paint-free
location on workpiece, as close to cutting
area as possible.
Raise trigger lock and press trigger. Pilot
arc starts. Move tip to within approxi-
mately 3/16 in. (4.8 mm). Start gouging
across workpiece surface. Maintain
approximately a 45 angle to surface.
Release trigger. Postflow continues for
approx. 20 seconds after releasing trigger;
arc can be instantly restarted during postflow
by raising trigger lock and pressing trigger.
! The pilot arc starts immediately
when trigger is pressed.
Hold torch at approximately
45 angle to workpiece.
Trigger pilot arc once before starting to gouge.
45