Miller Spectrum 625 X-TREME Owner's Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
. A complete Parts List is available at www.MillerWelds.com
OM-254 170 Page 22
Ref. 254 087-A
5-4. Plasma Cutting System Practices
Pulling rather than pushing the torch
makes cutting easier. Use a proper guide
or template for accurate cutting operations.
! The pilot arc starts immediately
when trigger is pressed.
Maintain approximately a 90
angle to the
workpiece surface for proper cutting results.
Always connect work clamp to a clean,
paint-free location on workpiece, as close to
cutting area as possible.
90
DO NOT start pilot arc without cutting or
gouging as this shortens the service life
of the nozzle and electrode.
Sparks should pass through the workpiece
and out the bottom when cutting.
If sparks flare back from surface, this
usually is an indication that either travel
speed is too fast or amperage is set too low.
When doing extended (non-shielded)
cutting, maintain approximately 1/16 in.
standoff between electrode and surface.
1/16 in.
(1.6 mm)
DO NOT put pressure on shield when
drag cutting; instead, slide shield along
the surface for proper cutting results.
Wt
Page view 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 43 44

Comments to this Manuals

No comments