OM-222 166 Page 30
A custom program can contain up to 10 segments. To view Program parameters, position the cursor at segment and use the Increase or
Decrease button to advance through the segment numbers until the End segment. When a segment number is changed, appropriate
segment parameter information appears on the display.
Typical 5-Segment Custom Program
Mode.......: Custom Program
Segment....: 1
Type.......:>Step
Temperature: 600
Custom Program Screen
Temperature increases to 600 degrees at full-programmed power.
Mode.......: Custom Program
Segment....: 2
Type.......: Ramp
Temperature:>1250 Ramp Rate: 600 _/Hr
Custom Program Screen
Controlled heating to 1250 degrees F at a ramp of 600 degrees per hour.
Mode.......: Custom Program
Segment....: 3
Type.......: Soak
Soak Time..:>01:00:00
Custom Program Screen
Soak at 1250 degrees F for a period of 1 hour.
Mode.......: Custom Program
Segment....: 4
Type.......:>Ramp
Temperature: 600 Ramp Rate: 600 _/Hr
Custom Program Screen
Controlled cooling to 600 degrees F at a rate of 600 degrees per hour.