Miller PipeWorx 400 Owner's Manual Page 57

  • Download
  • Add to my manuals
  • Print
  • Page
    / 116
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 56
OM-253 906 Page 51
B. Using Optional Memory Card
1. Memory Card Insertion
a. Lift and hold memory card access cover open.
b. Insert memory card into slot (push card all the way into slot and then release).
c. Close memory card access cover.
2. Memory Card Removal
a. Lift and hold memory card access cover open.
b. Push in and release memory card to eject card.
c. Grasp memory card and remove from slot.
d. Close memory card access cover.
3. Optional Program Card Operation
a. Insert optional program card into slot.
b. Select wire feeder as follows:
Press either the LEFT or RIGHT (dual feeder only) button on the feeder.
or
Press the SIDE SELECT button on the power source until the desired wire feeder side is illuminated.
c. Select weld process by pressing the MIG TYPE button on the power source front panel until the desired process is illuminated.
CARD will illuminate on the power source front panel as well as on the feeder front panel to indicate that the optional program is
being used from the memory card.
d. Select the wire diameter, if applicable, as follows:
Press the WIRE DIA button on the power source front panel until the desired wire diameter is illuminated.
. Some optional program cards only support a single wire diameter, in this case, only that diameter will illuminate.
e. Remove memory card to revert to standard operation.
4. Optional Feature Card Operation
a. Insert optional feature card.
b. Specific feature will be displayed on Volt meter of feeder.
c. Turn WFS knob to enable/disable feature.
d. Remove card.
. One card can enable/disable multiple machines.
5. Software Update Card (System Software Update)
a. Insert software update card into slot.
b. Perform software update by pressing and holding the LOAD button on the power source front panel until UPd appears on the 7-segment
LED display.
c. Wait for the software update to complete (approximately two minutes).
. During the software update, the displays on both the power source and feeder front panels may display H99 or H98 as well as the UPd or go blank
for a period of time. This is normal during a software update. Do not remove the memory card until the software update has completed. Do not
turn off the power source until the software update has completed.
d. Remove memory card.
C. Memory Locations
1. Memory Location Buttons 1-4
These are locations for storing weld process settings for easy access. Press and release these buttons to recall stored unit configuration settings. Only
one memory location can be active during unit operation. The number next to the button illuminates to indicate the active memory location. Unit configu-
ration settings are automatically saved to the active memory location one second after any change is made to any of the front panel controls. This
feature allows the unit to remember an operator’s preferred settings. These settings can be recalled at any time by selecting the appropriate memory
location and process/feeder side. By selecting a process such as STICK, TIG, MIG LEFT side of feeder, or MIG RIGHT side of feeder there will be four
Memory Locations available for each, providing a total of 16 Memory Locations for a dual feeder. There will only be 12 Memory Locations available for a
single feeder.
2. Memory Location Reset
Pressing and holding a memory location button for more than two seconds will restore factory default settings for the current weld process to that
particular memory location. The memory location number light will go out and back on when the reset is complete.