OM-253 906 Page 15
SECTION 4 SPECIFICATIONS
4-1. Important Information Regarding CE Products (Sold Within The EU)
A. Information On Electromagnetic Fields (EMF)
! This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 609741 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S The EMF assessment on this equipment was conducted at 0.5 meter.
S At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
B. Information On Electromagnetic Compatibility (EMC)
! This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
This equipment complies with IEC 61000312 provided that the shortcircuit power Ssc is greater than or equal to 9,138,888 at the interface
point between the user’s supply and the public system. It is the responsibility of the installer or user of the equipment to ensure, by consultation
with the distribution network operator if necessary, that the equipment is connected only to a supply with a shortcircuit power Ssc greater than
or equal to 9,138,888.
ce-emc 1 2011-09
4-2. General Specifications
A. Welding Power Source Specifications
Input
Power
Welding
Process
Rated Welding
Output
Amperage
Range
Setting (CC
Process)
Voltage
Range
Setting (CV
Process)
Maximum
Open-
Circuit
Voltage
DC
Amperes Input
At Rated Load
Output
50/60 Hz,
Three-Phase
KVA KW
380 V 400 V 380 400 380 400
Three
Phase
Stick
400 A @ 36 Volts
DC, 100% Duty
Cycle
40 400 — —
90
26.3 25.5 17.6 17.8 16.5 16.5
TIG
350 A @ 24 Volts
DC, 100% Duty
Cycle
10-350 — — 19.0 18.1 12.4 12.5 9.7 9.8
MIG
400 A @ 34 Volts
DC, 100% Duty
Cycle
— — 10-44 27.1 25.7 18 18 15.5 15.6
Flux
Cored
400 A @ 34 Volts
DC, 100% Duty
Cycle
— — 10-44 27.1 25.7 18 18 15.5 15.6
To appropriately size circuit protection see Section 5-10.