OM-116 Page 4
2-3. Connecting Input Power
ssb2.2 3/93 ST-155 576-B
Y Have only qualified persons
make this installation.
Tools Needed:
3/8 in
L2
L1
GND/PE
GND/PE
Connect First
Minimum input and grounding conductor size is 10
AWG/Kcmil, not to exceed 87 ft (26 m) in length. Install
conductors in conduit or equivalent into a deenergized
line disconnect device. Maximum recommended stan-
dard fuse or circuit breaker rating is 70 amperes. Size
and ratings must comply with applicable codes.
230 VAC,
1
GND/PE
L1 L2
Page view 5