Miller Millermatic 252 User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
2
Rated Output
200 A at 28 VDC,
60% Duty Cycle
250 A at 28 VDC,
40% Duty Cycle
Amperage
Range
30 300 A
Max.
Open-
Circuit
Voltage
38
Net
Weight
207 lb.
(94 kg)
Specifications
(Subject to change without notice.)
Amps Input at Rated Output, 60 Hz
200(208) V 230 V 460 V 575 V KVA KW
48 42 21 17 9.8 7.5
2.3* 2* 1* 0.8* 0.46* 0.13*
Wire Type and
Diameter
Solid/Stainless
Steel
.023 .045 in.
(0.6 – 1.2 mm)
Flux-Cored
.030 – .045 in.
(0.8 – 1.2 mm)
Wire Feed
Speed
50 700 IPM
(1.3 17.8
m/min.)
Dimensions
H: 30 in.
(762 mm)
W: 19 in.
(483 mm)
D: 40 in.
(1016 mm)
Max.
Spool
Size
12 in.
(305 mm)
10 20 30 40 50 60 70 80 90 100
50
100
150
200
250
300
350
400
450
500
WELD AMPS
DUTY CYCLE CHART
0
5
10
15
20
25
30
35
0 100 200 300 400
AMPERES% DUTY CYCLE
VOLT/AMP CURVES
VOLTS
MAX
MIN
Performance Data
3
4
1
2
Control Panel
1. Voltmeter
2. Voltage Control
3. Wire Speed Meter
4. Wire Speed Control
*While idling.
Note: Operating Temperature Range: -4° to +104°F (-20° to +40°C). Storage Temperature Range: -22° to +122° F (-30° to +50°C).
Certified by Canadian Standards Association to both the Canadian and U.S. Standards.
Page view 1
1 2 3 4 5 6 7 8

Comments to this Manuals