3
Control Panel
1. Voltmeter Display
2. Ammeter Display
3. Polarity AC/DC
4. Process/ TIG: HF Impulse, Lift Arc
Arc Starting STICK: Adaptive Hot Start
5. Output Control Standard Remote,
2T Trigger Hold,
Output ON
6. Encoder Control
7. Amperage Control
8. AC Waveshape
Balance 30– 99%
AC Frequency 20– 250 Hz
9. Gas/DIG Preflow 0.0 25.0 Seconds
Postflow 050 Seconds
DIG 0100%
Advanced features on the Dynasty DX only:
10. Sequencer Control
Initial Amps AC: 5 200 A
DC: 1– 200 A
Initial Slope 0.0 25.0 Seconds
Final Slope 0.0 25.0 Seconds
Final Amps AC: 5200 A
DC: 1– 200 A
11. Pulser Control
Pulses per Second DC: 0.1 500 PPS
AC: 0.1500 PPS
Peak Time 5 95%
Background Amps 5 – 95%
Control Panel Parameter Values
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
10
11
Dynasty 200 SD Dynasty 200 DX
Additional Setup Parameter Values
Preprogrammed Starts
.040 – 1/8 in Tungsten
Programmable Starts
Amperage AC: 5 200 A
DC: 1 200 A
Time 1 200 Milliseconds
Ramp Time 1 250 Milliseconds
Minimum Amperage 1– 20 A
Polarity EP, EN
Additional Triggers 3T, 4T, Mini Logic,
4T Momentary
Waveshapes Advance Squarewave,
Soft Squarewave, Sine
Wave, Triangular wave
Spot/Timer 0.1– 25.0 Seconds
OCV Low OCV, Normal OCV
Stick Stuck Check On/Off
Lockouts Four levels
Arc Timer 0.0 9999 Hours
and 059 Min
Cycle Counter 0 999,999 Cycles
Page view 14