4-8. Automation 10-Pin Connection (Optional)
Socket Socket Information For 10-Pin Receptacle RC3
A Start/Stop
Y Turn off power before
connecting to receptacle
B Gas
J
G
F
E
D
connecting to receptacle
C Output disabled
J
G
I
C
H
D
D Chassis ground
A
B
I
H
E Final slope − collector
A
F Final slope − emitter
Turn off power before
G Pulse lockout − collector
Ref. ST-801 972-C
Y Turn off power before
connecting to receptacle
H Pulse lockout − emitter
connecting to receptacle
I Valid arc − collector
J Valid arc − emitter
Definitions Of Inputs And Outputs
Inputs
A - Closure to D starts the weld cycle. Opening closure stops weld cycle. Durning 2T operation, a momentary closure (greater than 100ms, but
less than 3/4 seconds) starts and stops weld output.
B - Closure to D turns on gas. This input will override Postflow, but if a Preflow time is entered, the Preflow cycle will time out before arc initia-
tion.
C - Closure to D must be maintained at all times. If the closure between pins C and D is broken, an output disable occurs, Postflow begins to
time out, and HELP 13 will be displayed on the meters.
Outputs
Outputs are isolated open-collector transistor which are able to conduct at least 6 mA of current, with a maximum of 100 mA of current and 30
VDC.
Final Slope - output is on when in Final Slope.
Pulse Lockout - output is on when in Initial Amperage, Initial Slope, Final Slope, Final Amperage, and when the pulse frequency is less than 10
Hz.
Arc On - output is on when the contactor is on and there is less than 50 load volts.